CT-642 GTC Exhaust Gas Temperature
Technical Specifications
Part No.
|
R2-CT-642-MU
|
Range
|
0 - 800oC
|
Accuracy
|
+/- 0.5% FSD, +/- 1 DIGIT i.e. +/- 5oC
|
Temp. Alarm Setting
|
Alarm 510oC with Adjustable Facility of Setting throughout the range
|
Temp. Trip Setting
|
Trip - 550oC with Adjustable Facility of Setting throughout the rnage
|
Room Temp.
Compensation
|
Automatic (Self Compensation)
|
Remote & Local
Indicator
|
Facility is Available to connect 2 nos. remote indicator
in the field with Accuray of +/- 0.5^ FSD +/- 1 DIGIT
(Range: 0 - 800oC) |
Set Point
|
Alarm & Trip set point adjustable throughtout the range
inside the master controller enclosure
|
Relay
|
Two change over (One available on the terminal as per
drawing no ASR-06), and another is spare which is avialble
inside the enclosure) relay contact rating - 5A, 230V AC
|
Power Supply
|
1) Onboard Power supply Availble:
24V DC., +/- 10%, 1.5A with Battery Connected
in Parallel
2) Onboard 24 VDC to be connected to DC to DC converter
(Readiness check)
3) Master, Local & Remote Indicator works on 18V DC Derived
from DC to DC converter
|
Sensor
|
Thermocoupel type 'K' (CR/AL) 2 in series and 2 in Parallel
|
Sensor Accuracy
|
+- 3oC upto 400oC & 0.75% above 400oC |
Part No.
|
R2-TCK-CT-642.
|
|